  • Abstract
    The calibration of PMUs according to the standard IEEE C37.118.1 requires an important amount of data processing before the error on values such as TVE (Total Vector Error), FE (Frequency Error) or ROCOF (Rate Of Change Of Frequency) can be established. The aim of this paper is to present how this processing is implemented in the PMU reference grade calibrator developed at METAS. Calibration results made on a commercial PMU are also presented.
  • Keywords
    calibration; phasor measurement; FE; IEEE C37.118.1 standard; METAS; PMU; ROCOF; TVE; data processing; frequency error; phasor measurement unit; rate of change of frequency; reference grade calibrator; total vector error; Calibration; Data processing; IEEE standards; Iron; Phasor measurement units; Steady-state; IEEE C37.118.1-2011; PMU; Total Vector Error; dynamic performances; static performances; syncrophasor;