• DocumentCode
    2366524
  • Title

    Die level CDM testing duplicates assembly operation failures

  • Author

    Bernier, By Joe ; Croft, Gregg

  • Author_Institution
    Harris Semicond., Melbourne, FL, USA
  • fYear
    1996
  • fDate
    10-12 Sept. 1996
  • Firstpage
    117
  • Lastpage
    122
  • Abstract
    Field induced charged device model (FCDM) testing on individual dice has shown that die sort operations can cause electrostatic discharge (ESD) failures. CDM pulses as low as 100 volts to the back side of a die duplicated production failures. Static generated by the separation of dice from the wafer saw mounting film was found to be the underlying cause.
  • Keywords
    assembling; electrostatic discharge; failure analysis; integrated circuit testing; 100 V; CDM testing; assembly operation failure; dice separation; die sort; electrostatic discharge; field induced charged device model; wafer saw mounting film; Assembly; Electrostatic discharges; Failure analysis; Integrated circuit testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium, 1996. Proceedings
  • Print_ISBN
    1-878303-69-4
  • Type

    conf

  • DOI
    10.1109/EOSESD.1996.865133
  • Filename
    865133