DocumentCode
236822
Title
Control of single-phase AC/DC converter based on SOGI-PLL voltage synchronization
Author
Blahnik, Vojtech ; Kosan, Tomas ; Talla, Jakub
Author_Institution
Regional Innovation Centre for Electr. Eng., Univ. of West Bohemia, Plzeň, Czech Republic
fYear
2014
fDate
3-5 Dec. 2014
Firstpage
652
Lastpage
655
Abstract
This paper introduces the advanced control designed for the single-phase AC/DC traction converter. This type of control provides direct current control and sufficient control of output voltage. The proposed control strategy is based on second order general integrator phase locked loop (SOGI-PLL), which is used for trolley voltage synchronization. In this case SOGI-PLL evaluates voltage position, amplitude and frequency. These data are used for precise and robust current control, which uses PR controller. The behavior of designed control and SOGI-PLL synchronization is analyzed by both simulations and experiments made on developed 1.5 kW laboratory prototype.
Keywords
AC-DC power convertors; electric current control; phase locked loops; robust control; synchronisation; traction power supplies; voltage control; PR controller; SOGI-PLL voltage synchronization; direct current control; output voltage control; power 1.5 kW; robust current control; second order general integrator phase locked loop; single-phase AC-DC traction converter control; trolley voltage synchronization; voltage amplitude; voltage frequency; voltage position; Current control; Phase locked loops; Rectifiers; Synchronization; Vectors; Voltage control; Voltage measurement; AC/DC; SOGI-PLL; active rectifier; control algorithm; single-phase; synchronization;
fLanguage
English
Publisher
ieee
Conference_Titel
Mechatronics - Mechatronika (ME), 2014 16th International Conference on
Conference_Location
Brno
Print_ISBN
978-80-214-4817-9
Type
conf
DOI
10.1109/MECHATRONIKA.2014.7018337
Filename
7018337
Link To Document