Comparison of fingerprint quality measures using an optical and a capacitive sensor
Author :
Alonso-Fernandez, Fernando ; Roli, Fabio ; Marcialis, Gian Luca ; Fierrez, Julian ; Ortega-Garcia, Javier
Author_Institution :
Univ. Autonoma de Madrid, Madrid
fYear :
2007
fDate :
27-29 Sept. 2007
Firstpage :
1
Lastpage :
6
Abstract :
Although several image quality measures have been proposed for fingerprints, no work has taken into account the differences among capture devices, and how these differences impact on the image quality. In this paper, several representative measures for assessing the quality fingerprint images are compared using an optical and a capacitive sensor. The capability to discriminate between images of different quality and its relationship with the verification performance is studied. We report differences depending on the sensor, and interesting relationships between sensor technology and features used for quality assessment are also pointed out.
Keywords :
capacitive sensors; fingerprint identification; image sensors; optical sensors; capacitive sensor; fingerprint image quality; optical sensor; Biomedical optical imaging; Capacitive sensors; Fingerprint recognition; Image matching; Image quality; Image sensors; Optical devices; Optical sensors; Sensor phenomena and characterization; Skin;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biometrics: Theory, Applications, and Systems, 2007. BTAS 2007. First IEEE International Conference on
Conference_Location :
Crystal City, VA
Print_ISBN :
978-1-4244-1596-0
Electronic_ISBN :
978-1-4244-1597-7
Type :
conf
DOI :
10.1109/BTAS.2007.4401956
Filename :
4401956
Link To Document :
بازگشت