• DocumentCode
    2372247
  • Title

    A case history for assessing power requirements on line-shaft driven sections for the purpose of converting the sections to electrical sections

  • Author

    Jones, Walter V.

  • Author_Institution
    TM GE Autom. Syst. LLC, Salem, VA
  • fYear
    2008
  • fDate
    22-27 June 2008
  • Firstpage
    226
  • Lastpage
    230
  • Abstract
    A line-shaft drive paper machine was investigated while operating to determine the individual power requirement of each section. A step by step sequence of tests was developed to isolate the operating power requirements of each section. This paper documents the steps required for this power evaluation and generalizes the recommendations for other paper machines.
  • Keywords
    drives; paper making machines; shafts; electrical sections; line-shaft driven sections; operating power requirements; paper machine; power evaluation; Automation; Computer aided software engineering; DC motors; History; Paper making machines; Strontium; Torque; Turning; USA Councils; Wire; Drive Power; Drive Revamp; Line-shaft;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulp and Paper Industry Technical Conference, 2008. PPIC 2008. Conference Record of 2008 54th Annual
  • Conference_Location
    Seattle, WA
  • ISSN
    0190-2172
  • Print_ISBN
    978-1-4244-2524-2
  • Electronic_ISBN
    0190-2172
  • Type

    conf

  • DOI
    10.1109/PAPCON.2008.4585801
  • Filename
    4585801