DocumentCode :
2372247
Title :
A case history for assessing power requirements on line-shaft driven sections for the purpose of converting the sections to electrical sections
Author :
Jones, Walter V.
Author_Institution :
TM GE Autom. Syst. LLC, Salem, VA
fYear :
2008
fDate :
22-27 June 2008
Firstpage :
226
Lastpage :
230
Abstract :
A line-shaft drive paper machine was investigated while operating to determine the individual power requirement of each section. A step by step sequence of tests was developed to isolate the operating power requirements of each section. This paper documents the steps required for this power evaluation and generalizes the recommendations for other paper machines.
Keywords :
drives; paper making machines; shafts; electrical sections; line-shaft driven sections; operating power requirements; paper machine; power evaluation; Automation; Computer aided software engineering; DC motors; History; Paper making machines; Strontium; Torque; Turning; USA Councils; Wire; Drive Power; Drive Revamp; Line-shaft;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulp and Paper Industry Technical Conference, 2008. PPIC 2008. Conference Record of 2008 54th Annual
Conference_Location :
Seattle, WA
ISSN :
0190-2172
Print_ISBN :
978-1-4244-2524-2
Electronic_ISBN :
0190-2172
Type :
conf
DOI :
10.1109/PAPCON.2008.4585801
Filename :
4585801
Link To Document :
بازگشت