DocumentCode :
2373520
Title :
A preliminary study on estimation of energy expenditure at different locations of acceleration sensor during submaximal exercise
Author :
Kim, Taekyun ; Kim, Yonghyun ; Yoon, Hyungro ; Shin, Taemin
Author_Institution :
Dept. of Biomed. Eng., Yonsei Univ., Wonju, South Korea
fYear :
2009
fDate :
3-6 Sept. 2009
Firstpage :
4902
Lastpage :
4905
Abstract :
The purpose of this study is, for estimating energy expenditure with triaxial accelerometers during exercise, to compare determination coefficients of equations of the estimated regression according to several locations of the accelerometers on the body and then to present an estimation model on the location where there is the least restriction on physical activities. A small portable device that is able to obtain acceleration data during exercise was developed. It was attached on the back, wrist, knee and ankle of the body and then submaximal exercise was conducted on treadmills with the Bruce protocol. For the experimentation, seventeen males of twenties and thirties in good health (27.23plusmn2.18) participated and wore the equipment to analyze respiratory gas, so that the values of acceleration and energy expenditure from the respiratory gas analyzer could be obtained at the same time. The energy expenditure values from the outputs of the respiratory gas equipment were set as a base value, and the accelerations and the physical features of the participants (age, weight, height and BMI) as variables, to check each correlation, and for each of the four locations of the accelerometers on the body, regression analysis was carried out. The results of the experiment are as follows: the correlation between the acceleration and the energy expenditure was the highest on the knee and the lowest on the wrist; but, the determination coefficients (R2) of the regression equations using the continued hours of exercise, weight and acceleration values did not show significant difference among the locations on the body, as the highest R2=0.873 on the back and the lowest R2=0.852 on the wrist. This study has shown two possibilities. First, it is possible to predict energy expenditure using accelerometer sensor without respiration gas analyzer in laboratory situation. Second, these findings can be applied to application about predicting conveniently- - energy expenditure during outdoor activities using accelerometer on watch or shoes.
Keywords :
accelerometers; biomechanics; Bruce protocol; acceleration sensor; ankle; back; energy expenditure estimation; knee; respiratory gas; submaximal exercise; treadmills; triaxial accelerometers; wrist; Acceleration; Adult; Biosensing Techniques; Energy Metabolism; Exercise; Humans; Male; Regression Analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
Conference_Location :
Minneapolis, MN
ISSN :
1557-170X
Print_ISBN :
978-1-4244-3296-7
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2009.5332463
Filename :
5332463
Link To Document :
بازگشت