  • Abstract
    This article presents the study of an alternating voltage indirect conditioner, showing the main aspects of its digital and analog control. The generation of the sinusoidal reference for the output voltage control loop is discussed, both in analog and digital control, and for that purpose, a digital PLL based on the three-phase instantaneous power theory is proposed. On the analog controlled converter, an output voltage instantaneous control circuit is used. On the digital control proposed in this work, two circuits are used, one for input voltage feedforward, and one for controlling the effective output voltage. Experimental results obtained with a 10 kVA conditioner are presented
  • Keywords
    digital control; feedforward; phase locked loops; power convertors; voltage control; 10 kVA; AC indirect line conditioner digital control; PLL; alternating voltage indirect conditioner; analog controlled converter; input voltage feedforward; output voltage instantaneous control circuit; three-phase instantaneous power theory; voltage control loop; Circuits; Digital control; Filters; Frequency synchronization; Inductance; Phase locked loops; Pulse width modulation inverters; Switches; Switching converters; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    IEEE Industrial Electronics, IECON 2006 - 32nd Annual Conference on
  • Conference_Location
    Paris
  • ISSN
    1553-572X
  • Print_ISBN
    1-4244-0390-1
  • Type

    conf

  • DOI
    10.1109/IECON.2006.347762
  • Filename
    4153491