Abstract :
The authors present the results of a workshop held at Tokyo Metropolitan University for the purpose of investigating the measurement method and specifications for surface-mounted leadless crystal units, and obtaining actual data. It has been shown that unifying the basic specifications (PI circuit method) and the measurement software algorithm (proposed IEC specification) allows high-accuracy measurement to be conducted, even if different fixtures and measurement instruments are used
Keywords :
crystal resonators; electric variables measurement; equivalent circuits; quartz; surface mount technology; IEC specification; PI circuit method; SiO2; high-accuracy measurement; leadless resonator measurement; measurement instruments; measurement software algorithm; surface-mounted leadless crystal units; Calibration; Capacitance measurement; Electric variables measurement; Electrical resistance measurement; Frequency measurement; IEC standards; Impedance measurement; Inductance measurement; Instruments; Measurement standards;