Abstract :
In regulated electricity markets, there is trading of large volume of power over existing transmissions lines. Due to this, some corridors experience congestion and may endanger system security, stability and reliability. To overcome this, Unified Power Flow Controller (UPFC) can act as a decongestion device and can improve power flow. The proposed method uses a modified gravitational search algorithm to improve maximum power transfer capability of UPFC. This is tested on IEEE-57 bus system.
Keywords :
load flow control; maximum power point trackers; search problems; IEEE-57 bus system; UPFC optimal placement; decongestion device; gravitation based search algorithm; maximum power transfer capability; maximum power transfer improvement; modified gravitational search algorithm; unified power flow controller; Electrical engineering; Genetic algorithms; Load flow; Manganese; Power system stability; Power transmission lines; Congestion; UPFC; maximum power flow; optimal location;