Title :
Saturation measurements in AC machines using carrier signal injection
Author :
Aime, M.L. ; Degner, M.W. ; Lorenz, R.D.
Author_Institution :
Dipt. di Elettronica ed Inf., Politecnico di Milano, Italy
Abstract :
This paper presents a technique for measuring the position and magnitude of saliencies in AC machines by injecting a balanced, three-phase, carrier signal. The technique allows detection of where a machine saturates under a full range operating conditions, without any modification to the machine design or construction. From these measurements insight into the causes of saturation and suggestions for improvement in the machine design can be obtained. Experimental results on an induction machine show that saturation-induced saliencies can he significant at allow levels and are not fixed in position relative to any component of flux. Detailed analysis and discussion of the experimental results are included.
Keywords :
AC machines; machine testing; magnetic variables measurement; rotors; AC machines; carrier signal injection; machine construction; machine design; operating conditions; saliency magnitude; saliency position; saturation measurements; AC machines; Breakdown voltage; Inverters; Magnetic flux; Measurement techniques; Position measurement; Saturation magnetization; Stability; Stators; Torque;
Conference_Titel :
Industry Applications Conference, 1998. Thirty-Third IAS Annual Meeting. The 1998 IEEE
Conference_Location :
St. Louis, MO, USA
Print_ISBN :
0-7803-4943-1
DOI :
10.1109/IAS.1998.732276