DocumentCode
237839
Title
Study of calibration standards for extreme impedances measurement
Author
Haase, M. ; Hoffmann, Karel
Author_Institution
Dept. Of Electromagn. Field, Czech Tech. Univ. in Prague, Prague, Czech Republic
fYear
2014
fDate
6-6 June 2014
Firstpage
1
Lastpage
6
Abstract
The paper describes first results of pioneering research in the field of calibration standards for the measurement of extreme impedances. It is a necessary step for the measurement of extreme impedances since the method has been developed. The proposed calibration standards are based on coaxial microwave connector APC-7 and were extensively analyzed in CST Microwave Studio at the frequency range from 0.1 GHz to 18 GHz. Some of the analyzed structures seem to be promising for measurements of tiny very high impedance structures like carbon nanotubes or atto-farad varactors.
Keywords
calibration; electric impedance measurement; measurement standards; microwave measurement; APC-7 coaxial microwave connector; CST Microwave Studio; attofarad varactors; calibration standards; carbon nanotubes; extreme impedance measurement; frequency 0.1 GHz to 18 GHz; Calibration; Glass; Impedance measurement; Microwave measurement; Reflection coefficient; Standards; Strips; APC-7; CST Microwave Studio; Calibration standard; impedance measurement; microwave measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Measurement Conference (ARFTG), 2014 83rd ARFTG
Conference_Location
Tampa, FL
Type
conf
DOI
10.1109/ARFTG.2014.6899512
Filename
6899512
Link To Document