• DocumentCode
    2379812
  • Title

    A composite micromechanical model for connective tissue applied to rat tail tendon

  • Author

    Ault, Holly K. ; Hoffman, Allen H.

  • Author_Institution
    Dept. of Mech. Eng., Worcester Polytech. Inst., MA, USA
  • fYear
    1989
  • fDate
    27-28 Mar 1989
  • Firstpage
    207
  • Lastpage
    208
  • Abstract
    A micromechanical model of fibrous soft tissues has been developed which predicts upper and lower bounds on mechanical properties based on the structure and properties of tissue components. The model is useful in understanding the mechanical behaviour and interactions between soft-tissue constituents. For the highly organized structure of rat tail tendon, the upper-bound rule predicts uniform strain behavior in the material. A good correlation with experimental data is obtained
  • Keywords
    biomechanics; physiological models; composite micromechanical model; connective tissue; fibrous soft tissues; mechanical behaviour; mechanical interactions; mechanical properties bounds; rat tail tendon; strain behavior; Biological materials; Biological system modeling; Biological tissues; Composite materials; Connective tissue; Mechanical factors; Micromechanical devices; Predictive models; Tail; Tendons;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Bioengineering Conference, 1989., Proceedings of the 1989 Fifteenth Annual Northeast
  • Conference_Location
    Boston, MA
  • Type

    conf

  • DOI
    10.1109/NEBC.1989.36773
  • Filename
    36773