    Defibrillator synchronization tester

  • Author

    Demirbilek, Fatma N. ; Krajnak, Mike ; Stolarczyk, George

  • fYear
    2009
  • fDate
    3-6 Sept. 2009
  • Firstpage
    3012
  • Lastpage
    3015
  • Abstract
    A defibrillator sync output signal connector provides an ECG synchronization signal that can be used by some defibrillators for the purpose of performing synchronized cardioversion. This process is used to stop an abnormally fast heart rate or cardiac arrhythmia by the delivery of a therapeutic dose of electric current to the heart during the R-wave of the cardiac cycle. Timing the shock to the R-wave prevents the delivery of the shock during the vulnerable period of the cardiac cycle, which could induce ventricular fibrillation. GE patient monitors include a selectable analog output feature, which provides an analog ECG or arterial blood pressure signal. The blood pressure signal can be used to synchronize balloon pumps to provide cardiac assist to post-MI patients with poor injection fraction. Proper operation requires the defibrillator sync and analog output function to be checked. Checkouts are typically done during planned maintenance and after major part replacements such as patient monitor´s main CPU board. Checking out defibrillator sync signals could be done using a GE defibrillator sync tester. The defibrillator sync tester provides a loop back path for the defibrillator sync signals to be displayed on the patient monitor screen and eliminates the need for an external oscilloscope.
  • Keywords
    blood pressure measurement; cardiovascular system; defibrillators; diseases; electrocardiography; patient monitoring; CPU board; ECG synchronization signal; GE defibrillator synchronization tester; R-wave; analog ECG; arterial blood pressure signal; balloon pumps; cardiac arrhythmia; cardiac cycle; cardioversion; heart rate; patient monitor screen; post-MI patients; sync output signal connector; therapeutic dose; ventricular fibrillation; Arrhythmias, Cardiac; Blood Pressure; Cardiac Pacing, Artificial; Cardiopulmonary Resuscitation; Computer Simulation; Defibrillators; Electric Countershock; Electrocardiography; Equipment Design; Heart; Heart Conduction System; Humans;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-3296-7
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2009.5332840
  • Filename
    5332840