• DocumentCode
    2382039
  • Title

    Physiologic-state-adaptive recovery of aortic blood pressure and flow using blind 2-channel IIR cardiovascular system identification

  • Author

    Hahn, Jin-Oh ; Reisner, Andrew ; Asada, H. Harry

  • Author_Institution
    d´´Arbeloff Lab. for Inf. Syst. & Technol., Massachusetts Inst. of Technol., Cambridge, MA
  • fYear
    2008
  • fDate
    11-13 June 2008
  • Firstpage
    838
  • Lastpage
    843
  • Abstract
    This paper presents the development and analysis of a method to identify a two-channel cardiovascular system using two distinct peripheral blood pressure signals. The method is able to characterize the upper- and lower-limb arterial path dynamics as well as the aortic root impedance, and recover the aortic blood pressure and flow signals fed to it. The blind system identification and input de-convolution algorithms for a class of two-channel infinite impulse response systems are developed and applied to a gray-box model of a two-channel cardiovascular system. Persistent excitation condition, model identifiability and asymptotic variance are analyzed to quantify the method´s validity and reliability. Experimental results based on 83 data segments obtained from a swine subject show that the cardiovascular dynamics can be identified very accurately and reliably, and the aortic blood pressure and flow signals are stably recovered from two distinct peripheral blood pressure signals under diverse physiologic conditions. The benefit of the proposed method is demonstrated by comparing it to a predetermined transfer function describing the cardiovascular dynamics at nominal physiologic conditions.
  • Keywords
    IIR filters; blind source separation; blood pressure measurement; cardiovascular system; medical signal processing; aortic blood pressure; aortic root impedance; blind system identification; gray-box model; input de-convolution algorithm; peripheral blood pressure signal; physiologic-state-adaptive recovery; two-channel cardiovascular system; two-channel infinite impulse response system; Analysis of variance; Biomedical monitoring; Blood pressure; Cardiology; Cardiovascular system; Parameter estimation; Signal analysis; Signal processing; System identification; Transfer functions;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    American Control Conference, 2008
  • Conference_Location
    Seattle, WA
  • ISSN
    0743-1619
  • Print_ISBN
    978-1-4244-2078-0
  • Electronic_ISBN
    0743-1619
  • Type

    conf

  • DOI
    10.1109/ACC.2008.4586597
  • Filename
    4586597