DocumentCode
238318
Title
Induction motors-design, manufactured and test based on API 541
Author
Mistry, Rajendra ; Kreitzer, Scott
Author_Institution
Siemens Ind., Inc., Norwood, OH, USA
fYear
2014
fDate
3-5 June 2014
Firstpage
1
Lastpage
9
Abstract
Generally there are two types of end users of induction motors, i) Basic design based on IEC, NEMA [2] or some other standards and ii) basic design with the addition of the API 541[1] requirement. The second category is mostly used in refinery, power plant, and oil and gas industries where long term reliability is sought. This paper will discuss the basic design, manufacturing and testing and the additional requirements of API 541. In addition, this paper will help answer the following questions: what are API requirements, what benefits do they provide, and is the extra effort necessary or not? Finally it will conclude with the advantages and disadvantages of non API and API motors.
Keywords
IEC standards; design engineering; induction motors; machine testing; reliability; API 541 requirements; IEC standards; NEMA; design; induction motor manufacture; reliability; testing; Aluminum; Copper; Induction motors; Rotors; Shafts; Standards; Vibrations; API; IEC; Induction motor; NEMA; Standards;
fLanguage
English
Publisher
ieee
Conference_Titel
Petroleum and Chemical Industry Conference Europe, 2014
Conference_Location
Amsterdam
Type
conf
DOI
10.1109/PCICEurope.2014.6900071
Filename
6900071