• DocumentCode
    2384113
  • Title

    AC QHE-based calibration of resistance standards

  • Author

    Bohacek, J. ; Svoboda, P. ; Vasek, P.

  • Author_Institution
    Fac. of Electr. Eng., Czech Tech. Univ., Prague, Czech Republic
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    155
  • Lastpage
    156
  • Abstract
    A coaxial transformer bridge for QHE-based calibration of resistance standards has been developed. An 8-decade two-stage inductive voltage divider forms ratio arms of the bridge and triple-series connection of the reference QHE sample to the bridge is employed. Frequency characteristics of LEP heterostructures have been measured by comparing them against resistors with calculable frequency dependences. Two quadrifilar, Gibbings´s type resistors with nominal values of 12906 /spl Omega/ and 6453 /spl Omega/ have been used in this measurement.
  • Keywords
    calibration; electric resistance measurement; measurement standards; quantum Hall effect; 12906 ohm; 6453 ohm; AC QHE; LEP heterostructure; calibration; coaxial transformer bridge; frequency characteristics; inductive voltage divider; quadrifilar Gibbings type resistor; resistance standard; triple-series connection; Bridge circuits; Calibration; Coaxial cables; Frequency; Helium; Length measurement; Measurement standards; Resistors; Superconducting magnets; Temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.546666
  • Filename
    546666