DocumentCode
2384374
Title
The improvement program for higher intensity and better quality in the Princeton University cyclotron
Author
Huang, Y. ; Kidner, S. ; Yoon, M. ; Oh, S.
Author_Institution
Dept. of Phys., Princeton Univ., NJ, USA
fYear
1989
fDate
20-23 Mar 1989
Firstpage
845
Abstract
A new design of the second-harmonic central region for the Princeton cyclotron has been carried out. Extensive beam extraction studies based on the new design have also been performed. These studies suggest that modifications to the shape of the electrostatic deflector can lead to greater extraction efficiency. This result is consistent with the observed burn marks created by the beam in the present extraction region. Further improvements will also be introduced to increase the power dissipation that can be tolerated in the extraction septum
Keywords
beam handling equipment; cyclotrons; particle beam diagnostics; Princeton University cyclotron; beam extraction studies; electrostatic deflector; extraction efficiency; extraction septum; power dissipation; second-harmonic central region; Acceleration; Cyclotrons; Energy resolution; Ion accelerators; Particle beams; Physics; Power supplies; Power system reliability; Radio frequency; Stability;