ECG data compression by biorthogonal basis
Author
Kiryu, Tohru ; Kodaira, Naoaki ; Ogawa, Hidemitsu ; Saitoh, Yoshiaki
Author_Institution
Dept. of Inf. Eng., Niigata Univ., Japan
fYear
1994
fDate
1994
Firstpage
1266
Abstract
The authors propose a new transformation method as an electrocardiogram (ECG) data compression. They use a biorthogonal basis in the restoring procedure to overcome shortcomings in the existing transformation methods. Using the biorthogonal basis, nonuniformly selected original amplitude can be used in the restoring procedure instead of the transformation coefficients of conventional methods. Flexibility in selection of amplitude samples will be useful to produce a reasonable ECG data compression depending on the demand of a cardiologist
Keywords
electrocardiography; ECG data compression; amplitude samples selection flexibility; biorthogonal basis; medical signal compression; nonuniformly selected original amplitude; restoring procedure; transformation coefficients; transformation method; Cardiology; Data compression; Data engineering; Data processing; Databases; Eigenvalues and eigenfunctions; Electrocardiography; Hospitals; Karhunen-Loeve transforms; Sampling methods;