• DocumentCode
    2391638
  • Title

    Measurement of the attenuation coefficient for monodisperse populations of ultrasound contrast agents

  • Author

    Gong, Yanjun ; Cabodi, Mario ; Porter, Tyrone M.

  • Author_Institution
    Dept. of Mech. Eng., Boston Univ., Boston, MA, USA
  • fYear
    2009
  • fDate
    3-6 Sept. 2009
  • Firstpage
    1964
  • Lastpage
    1966
  • Abstract
    In this paper, we describe a technique for producing populations of ultrasound contrast agents (UCA) with a narrow size distribution. Using acoustic techniques, we measure the frequency-dependent attenuation coefficient for suspensions of ultrasound contrast agents with varying size distributions, ranging from narrow to wide. Our results demonstrate that as the size distribution becomes more uniform, attenuation occurs within a narrow frequency range. Additionally, as the mean size decreases, the peak in the attenuation coefficient occurs at a higher frequency.
  • Keywords
    bioMEMS; biomedical materials; biomedical ultrasonics; microfluidics; suspensions; ultrasonic absorption; ultrasonic imaging; attenuation coefficient measurement; frequency dependent attenuation coefficient; ultrasound contrast agent monodisperse populations; ultrasound contrast agent suspensions; Contrast Media; Disease Progression; Equipment Design; Humans; Microbubbles; Microfluidics; Solutions; Ultrasonics; Ultrasonography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-3296-7
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2009.5333441
  • Filename