• DocumentCode
    2395407
  • Title

    Pecision voltage regulation on the 5 KHz, 3.125 MW ETA-II pulsed power system

  • Author

    Watson, J.A. ; Payne, A.N. ; Sampayan, S.E. ; Ollis, C.W.

  • Author_Institution
    University of California
  • fYear
    1991
  • fDate
    16-19 June 1991
  • Firstpage
    221
  • Lastpage
    223
  • Abstract
    Each of four pulsed power units (PPUs) for the Experimetnal Test Acceleraot II (ETA-II) at Lawrence Livermore National Laboratory delivers a 25 kV, 20 kA, 4/spl mu/S pulse at a 5kHz repetition rate into a pulse compression modulator (MAG-ID). In our present configuration, we are capable of producing a 50 pulse burst using a 1000/spl mu/F capacitor bank. In this configuration, the input voltage to the PPU droops 22% udring the burst. Accelerator operating requirements, however, dictate /spl I.chemo/0.1% regulation of the PPU output voltage during burst. We are employing a de-Qing network to achieve this goal. In this paper, we describe an output voltage predict-ahead scheme that we are using to generate de-Q trigger pulses at the proper time to insure accurate regulation.
  • Keywords
    Capacitors; Cyclic redundancy check; Delay effects; Delay systems; Pulse amplifiers; Pulse power systems; Switches; Thyratrons; Timing; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 1991. Digest of Technical Papers. Eighth IEEE International
  • Conference_Location
    San Diego, CA, USA
  • Print_ISBN
    0-7803-0177-3
  • Type

    conf

  • DOI
    10.1109/PPC.1991.733272
  • Filename