Modelling and control of the single-phase dc-ac PWM converter for grid-connected applications including a loop for average primary current controlling
Author
Coelho, Roberto F. ; Lazzarin, Telles B. ; Martins, Denizar C.
Author_Institution
Power Electron. Inst., Fed. Univ. of Santa Catarina, Florianópolis, Brazil
fYear
2011
fDate
11-15 Sept. 2011
Firstpage
334
Lastpage
340
Abstract
This work presents a complete analysis of the single-phase bidirectional PWM dc-ac converter for grid-connected applications. Traditionally, this converter contains two control loops (instantaneous grid current and dc bus voltage), but, as in this work a low frequency transformer is employed for the grid-connection, a third control loop is proposed, in order to compensate any primary transformer average current. This additional control loop is added to avoid the transformer saturation, since the grid current sensor, placed at the secondary, cannot measure the primary average current component, impeding the traditional control system to compensate it. The dc-ac converter modeling is performed considering the low frequency transformer dynamic and simulation results are presented to validate the analysis.
Keywords
DC-AC power convertors; PWM power convertors; electric current control; power system control; transformers; grid current sensor; primary current controlling; primary transformer; single-phase dc-ac PWM converter; Windings; Converter Modeling Grid-connected Systems; Low Frequency Transformer; dc-dc Converter;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Electronics Conference (COBEP), 2011 Brazilian
Conference_Location
Praiamar
ISSN
2175-8603
Print_ISBN
978-1-4577-1644-7
Electronic_ISBN
2175-8603
Type
conf
DOI
10.1109/COBEP.2011.6085259
Filename
6085259
Link To Document