Improvement of lightning protection against direct strokes
Author
Carpenter, Roy B., Jr. ; Drabkin, Mark M.
Author_Institution
Lightning Eliminators & Consultants Inc., Boulder, CO, USA
fYear
1997
fDate
18-22 Aug 1997
Firstpage
403
Lastpage
405
Abstract
Implementation of the multi-point discharge system (MPDS) instead of conventional lightning rods results in significant improvement of the lightning protection of the premises. The full size of the properly designed and installed MPDS prevents the direct lightning strokes into the protected area, while the MPDS of lesser size with reduced number of points of discharge significantly decrease the number of the direct strokes occurrence with an increased zone of protection compared to the protective zone of the lightning rod
Keywords
lightning protection; direct strokes; lightning protection improvement; multi-point discharge system; zone of protection; Electronic equipment; Fires; Grounding; Lightning protection; Magnetic fields; Optical propagation; Quality of service; Safety; Telephony; Wires;