DocumentCode :
2397180
Title :
X ray diagnostics of high-current E-beams
Author :
Kotov, Yu A. ; Sokovnin, S.Yu.
Author_Institution :
USSR Academy of Sciences
fYear :
1991
fDate :
16-19 June 1991
Firstpage :
629
Lastpage :
632
Abstract :
It is proposed to determine the electron energy, by the filter method which consists in determining the cross section of the attenuation of braking radiation in the filter material, i.e., an effective energy of the braking radiation equal to a half of E. The method is distinguished by that measurements are made in the narrow beam geometry. Current density at the target is proposed to be measured by using two detector, the first one being placed in a site where the dimensions of the braking readiation source affect its readings, while the other being positioned so that this effect is absent. The method was verified on the VIRA-1.5M X-ray generator.
Keywords :
Attenuation; Collimators; Energy measurement; Filters; Particle scattering; Radiation detectors; Thickness measurement; X-ray detection; X-ray detectors; X-ray scattering;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 1991. Digest of Technical Papers. Eighth IEEE International
Conference_Location :
San Diego, CA, USA
Print_ISBN :
0-7803-0177-3
Type :
conf
DOI :
10.1109/PPC.1991.733361