DocumentCode :
2397788
Title :
Analysis of rotor faults in three phase induction machines
Author :
Sutherland, Peter E. ; Salon, Sheppard J.
Author_Institution :
Electr. Power Eng., Rensselaer Polytech. Inst., Troy, NY, USA
Volume :
3
fYear :
2002
fDate :
13-18 Oct. 2002
Firstpage :
1548
Abstract :
The detection of broken rotor bars in three-phase induction machines by means of current signature analysis is simulated by transient analysis. Expressions are derived for all self- and mutual-inductances between individual stator coils and rotor bar loops. This detailed modeling allows for greater precision in identifying the magnitude and frequency of the current harmonics present under fault conditions. Computations were performed using the trapezoidal method. The results of this analysis are in agreement with results presented in the literature.
Keywords :
fault diagnosis; harmonics; inductance; induction motors; rotors; stators; 12000 hp; 13.8 kV; 3-phase induction motors; broken rotor bar faults detection; current harmonics; current signature analysis; fault conditions; mutual-inductances; rotor bar loops; rotor faults analysis; self-inductances; stator coils; transient analysis; Analytical models; Coils; Fault detection; Inductance; Induction machines; Induction motors; Monitoring; Rotors; Stators; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industry Applications Conference, 2002. 37th IAS Annual Meeting. Conference Record of the
Conference_Location :
Pittsburgh, PA, USA
ISSN :
0197-2618
Print_ISBN :
0-7803-7420-7
Type :
conf
DOI :
10.1109/IAS.2002.1043740
Filename :
1043740
Link To Document :
بازگشت