Title :
Variable Ionizing Radiation Pulse Shape At The Aurora
Author :
Bushell, Michael ; Fleetwood, Raymond ; Merkel, George ; Smith, Michael
Author_Institution :
Harry Diamond Laboratories
Abstract :
With nose erosion and beam diversion combined, a single output of Aurora´s four diode units can produce ionizing radiation pulse risetimes from 10 to 50 ns. The full width half maximum (FWHM) of a single-output can be varied from 15 to 150 ns. Recent modifications that reduced the jitter between the four separate diodes have made possible a mode of operation involving four separate diodes, in which the combined risetime can be varied from about 18 to 80 ns and the FWHM from about 30 to 150 ns. A variable pulse shape should allow a system model to be tested over a large volume of stress parameter space.
Keywords :
Diodes; Electron beams; Electron tubes; Insulation; Ionizing radiation; Jitter; Nose; Pulse shaping methods; Shape; Testing;
Conference_Titel :
Pulsed Power Conference, 1991. Digest of Technical Papers. Eighth IEEE International
Conference_Location :
San Diego, CA, USA
Print_ISBN :
0-7803-0177-3
DOI :
10.1109/PPC.1991.733410