DocumentCode
2398467
Title
Tetrahedral and polyhedral mesh evaluation for cerebral hemodynamic simulation — A comparison
Author
Spiegel, Martin ; Redel, Thomas ; Zhang, Y. Jonathan ; Struffert, Tobias ; Hornegger, Joachim ; Grossman, Robert G. ; Doerfler, Arnd ; Karmonik, Christof
Author_Institution
Dept. of Comput. Sci., Friedrich-Alexander Univ. Erlangen-Nuremberg, Erlangen, Germany
fYear
2009
fDate
3-6 Sept. 2009
Firstpage
2787
Lastpage
2790
Abstract
Computational fluid dynamic (CFD) based on patient-specific medical imaging data has found widespread use for visualizing and quantifying hemodynamics in cerebrovascular disease such as cerebral aneurysms or stenotic vessels. This paper focuses on optimizing mesh parameters for CFD simulation of cerebral aneurysms. Valid blood flow simulations strongly depend on the mesh quality. Meshes with a coarse spatial resolution may lead to an inaccurate flow pattern. Meshes with a large number of elements will result in unnecessarily high computation time which is undesirable should CFD be used for planning in the interventional setting. Most CFD simulations reported for these vascular pathologies have used tetrahedral meshes. We illustrate the use of polyhedral volume elements in comparison to tetrahedral meshing on two different geometries, a sidewall aneurysm of the internal carotid artery and a basilar bifurcation aneurysm. The spatial mesh resolution ranges between 5,119 and 228,118 volume elements. The evaluation of the different meshes was based on the wall shear stress previously identified as a one possible parameter for assessing aneurysm growth. Polyhedral meshes showed better accuracy, lower memory demand, shorter computational speed and faster convergence behavior (on average 369 iterations less).
Keywords
bifurcation; blood flow measurement; blood vessels; brain; computational fluid dynamics; diagnostic radiography; diseases; flow simulation; flow visualisation; image reconstruction; medical image processing; mesh generation; neurophysiology; stress analysis; 3D digital subtraction angiography; CFD simulation; basilar bifurcation aneurysm; blood flow simulation; cerebral aneurysms; cerebral hemodynamic simulation; cerebrovascular disease; coarse spatial resolution; computational fluid dynamics; hemodynamics quantification; hemodynamics visualization; image reconstruction; internal carotid artery; patient-specific medical imaging data; polyhedral mesh evaluation; sidewall aneurysm; spatial mesh resolution; stenotic vessels; tetrahedral mesh evaluation; vascular pathologies; wall shear stress; Angiography; Automation; Blood Flow Velocity; Carotid Arteries; Cerebrovascular Circulation; Computer Simulation; Computers; Constriction, Pathologic; Equipment Design; Hemodynamics; Humans; Imaging, Three-Dimensional; Intracranial Aneurysm; Models, Theoretical; Reproducibility of Results;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
Conference_Location
Minneapolis, MN
ISSN
1557-170X
Print_ISBN
978-1-4244-3296-7
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/IEMBS.2009.5333829
Filename
5333829
Link To Document