Abstract :
This paper provides a comparison between direct torque-flux control (DTFC) and vector control (VC) techniques for salient type permanent magnet synchronous motor (PMSM) drive in the context of loss minimization and dynamic responses. The same model based loss minimization algorithm (LMA) is utilized with both DTFC and VC based PMSM drives to compare their efficiency performances. It is found from simulation results that the LMA based DTFC provides better efficiency than that of LMA based VC technique. On the other hand, the VC technique provides better dynamic response than that of DTFC based PMSM drive.
Keywords :
dynamic response; machine control; magnetic flux; permanent magnet motors; synchronous motor drives; torque control; DTFC based PMSM drive; LMA based DTFC; LMA based VC technique; direct torque-flux control; dynamic responses; loss minimization algorithm; salient type permanent magnet synchronous motor drive; vector control techniques; Hysteresis motors; Machine vector control; Minimization; Permanent magnet motors; Torque; Vectors; Direct torque-flux control; Permanent magnet synchronous motor; dynamic response; loss minimization; vector control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical and Computer Engineering (CCECE), 2014 IEEE 27th Canadian Conference on
Conference_Location :
Toronto, ON
ISSN :
0840-7789
Print_ISBN :
978-1-4799-3099-9
Type :
conf
DOI :
10.1109/CCECE.2014.6900971
Filename :
6900971
Link To Document :
بازگشت