Title :
Impact of Inductor Placement on the Performance of Adjustable Speed Drives Under Input Voltage Unbalance and Sag Conditions
Author :
Lee, Kevin ; Jahns, Thomas M. ; Novotny, D.W. ; Lipo, Thomas A. ; Berkopec, William E. ; Blasco, V.
Author_Institution :
Eaton Corp., Milwaukee, WI
Abstract :
Voltage unbalance or sag conditions generated by the line excitation can cause the input rectifier stage of an adjustable-speed drive (ASD) to enter single-phase rectifier operation. This degradation of the input power quality can have a significant negative impact on the induction machine performance characteristics, but the presence of an LC filter in the drive´s input rectifier stage can be used to attenuate these undesired effects. The purpose of this paper is to investigate the impact of the inductor placement in the ASB topology on the drive´s performance under voltage unbalance or sag conditions. More specifically, the relative advantages of choosing either a DC link choke inductor or three AC line inductors are discussed using a combination of closed-form analysis and simulations. The results of first-order sizing calculations show that a DC link choke inductor may offer some volume and mass advantages over three separate ac line inductors for the same ASD performance under unbalanced voltage conditions. Experimental results using a 5 hp ASD confirm the key analytical performance predictions
Keywords :
induction motor drives; power filters; power inductors; power supply quality; rectifying circuits; variable speed drives; DC link choke inductor; LC filter; adjustable speed drives; closed-form analysis; first-order sizing calculations; induction machine performance; inductor placement; power quality; single-phase rectifier operation; voltage sag conditions; voltage unbalance; Degradation; Filters; Induction generators; Induction machines; Inductors; Power quality; Rectifiers; Topology; Variable speed drives; Voltage fluctuations;
Conference_Titel :
Electric Machines and Drives, 2005 IEEE International Conference on
Conference_Location :
San Antonio, TX
Print_ISBN :
0-7803-8987-5
Electronic_ISBN :
0-7803-8988-3
DOI :
10.1109/IEMDC.2005.195906