• DocumentCode
    2402487
  • Title

    Results from geometric and radiometric calibration of TerraSAR-X

  • Author

    Bräutigam, B. ; Schwerdt, M. ; Bachmann, M. ; Döring, B.

  • Author_Institution
    Microwaves & Radar Inst. Oberpfaffenhofen, Wessling
  • fYear
    2007
  • fDate
    10-12 Oct. 2007
  • Firstpage
    87
  • Lastpage
    90
  • Abstract
    TerraSAR-X is a scientific and commercial SAR mission to be launched in June 2007. As it provides high-resolution products for a multitude of operation modes and incidence angles, the radiometric and geometric calibration of TerraSAR-X has to ensure the product quality and the correct in-orbit operation of the entire SAR system. This paper describes the calibration activities for TerraSAR-X and the dedicated tasks to be performed during the five months commissioning phase. Results from on-ground tests are discussed with respect to geometric and radiometric calibration of the TerraSAR-X system.
  • Keywords
    calibration; radiometry; spaceborne radar; synthetic aperture radar; SAR mission; TerraSAR-X satellite; correct in-orbit operation; geometric calibration; on-ground tests; operation modes; product quality; radiometric calibration; synthetic aperture radar; Antenna arrays; Antenna measurements; Azimuth; Calibration; Instruments; Microwave radiometry; Phased arrays; Polarization; Satellite broadcasting; Spaceborne radar;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radar Conference, 2007. EuRAD 2007. European
  • Conference_Location
    Munich
  • Print_ISBN
    978-2-87487-004-0
  • Type

    conf

  • DOI
    10.1109/EURAD.2007.4404943
  • Filename
    4404943