• DocumentCode
    2402559
  • Title

    A sensitive device for the measurement of the force exerted by an arc on the electrodes

  • Author

    Chabrerie, J.P. ; Devautour, J. ; Gouega, A.M. ; Testé, Ph

  • Author_Institution
    Lab. de Genie Electr., Paris VI Univ., France
  • fYear
    1994
  • fDate
    17-19 Oct. 1994
  • Firstpage
    261
  • Lastpage
    267
  • Abstract
    In this paper a very sensitive device allowing the measurement of the forces exerted on an electrode by an electric arc is presented. The device principle is based on the use of a piezo-electric transducer. The calibration of the device is explained and experimental results are presented on the force exerted on various electrode materials (Ag and AgSnO2) for cathodes and for anodes. Force measurements have also been realised for various cover gases (air and argon), for various electrode gaps and for various arc current pulse durations, showing the relevance of such a diagnostic means for an electric arc.
  • Keywords
    arcs (electric); calibration; electrodes; force measurement; piezoelectric transducers; Ag; AgSnO2; Ar; air; calibration; cover gases; current pulse; diagnostics; electric arc; electrodes; force measurement; piezoelectric transducer; Anodes; Argon; Calibration; Cathodes; Electric variables measurement; Electrodes; Force measurement; Gases; Pulse measurements; Transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Contacts, 1994. Proceedings of the Fortieth IEEE Holm Conference on Electrical Contacts
  • Print_ISBN
    0-7803-2133-2
  • Type

    conf

  • DOI
    10.1109/HOLM.1994.636846
  • Filename
    636846