• DocumentCode
    2404216
  • Title

    High frequency limitations of the JEDEC 123 guideline

  • Author

    Williams, Dylan F.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Boulder, CO, USA
  • fYear
    1998
  • fDate
    26-28 Oct 1998
  • Firstpage
    54
  • Lastpage
    57
  • Abstract
    This paper assesses certain systematic high frequency measurement errors inherent in the procedures described in the JEDEC 123 guideline for measurement of electronic package inductance and capacitance model parameters
  • Keywords
    capacitance measurement; error analysis; inductance measurement; integrated circuit measurement; integrated circuit modelling; measurement errors; measurement standards; JEDEC 123 guideline; electronic package capacitance; electronic package inductance; electronic package inductance/capacitance model parameter measurement; high frequency limitations; model parameters; systematic high frequency measurement errors; Capacitance measurement; Circuit simulation; Electronics packaging; Frequency estimation; Frequency measurement; Guidelines; Impedance measurement; Inductance measurement; Pins; Transmission line measurements;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Performance of Electronic Packaging, 1998. IEEE 7th Topical Meeting on
  • Conference_Location
    West Point, NY
  • Print_ISBN
    0-7803-4965-2
  • Type

    conf

  • DOI
    10.1109/EPEP.1998.733749
  • Filename
    733749