• DocumentCode
    2404700
  • Title

    PWM drive overvoltage trips in electrochemical plants

  • Author

    Buddingh, Paul ; Mars, Jack St

  • Author_Institution
    ANDRITZ Autom. Ltd., Richmond, BC, Canada
  • fYear
    2011
  • fDate
    19-21 Sept. 2011
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Case study application paper for a recurring problem the authors have recently experienced in electrochemical plants using low voltage PWM ASD´s. Low voltage ASD´s are tripping on 1.3 per unit voltage switching transients lasting 1-3 cycles. The ubiquitous ASD has been so successful that it is now used on critical plant processes that cannot tolerate outages. Most power system components are built to operate with a significant level of transient voltage resilience. This does not appear be the case for some of the low voltage ASD´s in use today. This paper examines this issue and provides a specifying methodology for new ASD´s, field proven cost effective corrective measures for installed ASD´s, and a case study.
  • Keywords
    PWM rectifiers; overvoltage; switching transients; ASD; PWM; electrochemical plants; overvoltage trip; switching transients; transient voltage resilience; Harmonic filters; Inductors; Power systems; Transient analysis; Variable speed drives; Voltage control; ASD; PWM; VFD; capacitor bank; harmonic filter; overvoltage trip; switching transient; transient voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Petroleum and Chemical Industry Conference (PCIC), 2011 Record of Conference Papers Industry Applications Society 58th Annual IEEE
  • Conference_Location
    Toronto, ON
  • ISSN
    0090-3507
  • Print_ISBN
    978-1-61284-299-8
  • Type

    conf

  • DOI
    10.1109/PCICon.2011.6085866
  • Filename
    6085866