• DocumentCode
    2409820
  • Title

    Backside GMR Magnetic Microscopy for flip chip and related microelectronic devices

  • Author

    Hechtl, M.

  • Author_Institution
    Infineon Technol. AG Munich, Munich
  • fYear
    2008
  • fDate
    7-11 July 2008
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    The applicability of GMR Magnetic Microscopy for current paths on flip chip die and interposer is shown. For non thinned samples (200 mum die thickness), interposer currents may be attributed to the interposer signal routing in the 1 mA current regime. With decreasing die thickness the discrimination of on-die currents versus interposer currents becomes possible. Below about 80 mum die thickness, on-die current paths, carrying sub-100 muA currents may be identified by comparison with die layout.
  • Keywords
    failure analysis; flip-chip devices; giant magnetoresistance; GMR magnetic microscopy; current paths; die thickness; flip chip; interposer currents; microelectronic devices; on-die currents; signal routing; Current distribution; Flip chip; Magnetic field measurement; Magnetic sensors; Magnetization; Microelectronics; Micromagnetics; Packaging; SQUIDs; Sensor arrays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits, 2008. IPFA 2008. 15th International Symposium on the
  • Conference_Location
    Singapore
  • Print_ISBN
    978-1-4244-2039-1
  • Electronic_ISBN
    978-1-4244-2040-7
  • Type

    conf

  • DOI
    10.1109/IPFA.2008.4588181
  • Filename
    4588181