DocumentCode
2409820
Title
Backside GMR Magnetic Microscopy for flip chip and related microelectronic devices
Author
Hechtl, M.
Author_Institution
Infineon Technol. AG Munich, Munich
fYear
2008
fDate
7-11 July 2008
Firstpage
1
Lastpage
4
Abstract
The applicability of GMR Magnetic Microscopy for current paths on flip chip die and interposer is shown. For non thinned samples (200 mum die thickness), interposer currents may be attributed to the interposer signal routing in the 1 mA current regime. With decreasing die thickness the discrimination of on-die currents versus interposer currents becomes possible. Below about 80 mum die thickness, on-die current paths, carrying sub-100 muA currents may be identified by comparison with die layout.
Keywords
failure analysis; flip-chip devices; giant magnetoresistance; GMR magnetic microscopy; current paths; die thickness; flip chip; interposer currents; microelectronic devices; on-die currents; signal routing; Current distribution; Flip chip; Magnetic field measurement; Magnetic sensors; Magnetization; Microelectronics; Micromagnetics; Packaging; SQUIDs; Sensor arrays;
fLanguage
English
Publisher
ieee
Conference_Titel
Physical and Failure Analysis of Integrated Circuits, 2008. IPFA 2008. 15th International Symposium on the
Conference_Location
Singapore
Print_ISBN
978-1-4244-2039-1
Electronic_ISBN
978-1-4244-2040-7
Type
conf
DOI
10.1109/IPFA.2008.4588181
Filename
4588181
Link To Document