• DocumentCode
    2412414
  • Title

    Electrical stability during vibration and electromagnetic pulse survivability of silver-plated glass bead filled EMI shielding gaskets

  • Author

    Walther, James F.

  • Author_Institution
    Potters Ind. Inc., Carlstadt, NJ, USA
  • fYear
    1989
  • fDate
    23-25 May 1989
  • Firstpage
    40
  • Lastpage
    45
  • Abstract
    Commercial sources of conductive silicone gaskets for electromagnetic interference (EMI) shielding filled with silver-plated glass microspheres were highly stable under conditions of severe vibration and intense simulated electromagnetic pulse (EMP). The results are in contrast to data published by C.H. Kuist (1977) and may demonstrate a considerable advancement in EMI gasket and conductive filler manufacturing technologies. The data showed there is no longer reason for concern over vibration and EMP stabilities of silver-glass gaskets
  • Keywords
    electromagnetic interference; glass; magnetic shielding; silver; vibrations; Ag plated glass beads; EMI shielding gaskets; EMP shielding; conductive silicone gaskets; electrical stability; electromagnetic pulse survivability; vibration; Aerospace materials; Copper; EMP radiation effects; Electromagnetic interference; Electronic equipment testing; Gaskets; Glass; Resonance; Stability; Vibration measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1989., IEEE 1989 National Symposium on
  • Conference_Location
    Denver, CO
  • Type

    conf

  • DOI
    10.1109/NSEMC.1989.37148
  • Filename
    37148