DocumentCode :
2414978
Title :
Elimination of leakage effects related to the use of windings with fractions of turns
Author :
Perica, Goran
Author_Institution :
Sperry Ine., Electronic Systems Dorval, Quebec, Canada
fYear :
1984
fDate :
18-21 June 1984
Firstpage :
268
Lastpage :
278
Abstract :
Obtaining exact output voltages from transformers is a difficult task due to discrete turns ratios. This becomes even more difficult in modern switching power supplies, operating above 100kHz, because the number of turns per winding is reduced. For multi-channel applications different methods of postregulation have been employed, resulting in increased power dissipation and power supply cost, A new method of dealing with this problem has been developed, offering a higher degree of flexibility. This technique al lows the use of fractions of turns, while maintaining low leakage inductances. Theoretical analysis of leakage effects related to fractional turn windings has been derived and tests on an experimental transformer have been performed.
Keywords :
Inductance; Magnetic cores; Magnetic flux; Magnetic switching; Power supplies; Power transformers; Windings;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1984 IEEE
Conference_Location :
Gaithersburg, MD, USA
ISSN :
0275-9306
Type :
conf
DOI :
10.1109/PESC.1984.7083488
Filename :
7083488
Link To Document :
بازگشت