Title :
Transient performance comparison on digital peak current controlled switching dc-dc converters in DCM with different digital pulse-width modulations
Author :
Zhou, Guohua ; Xu, Jianping ; Jin, Yanyan ; Wang, Wei
Author_Institution :
Sch. of Electr. Eng., Southwest Jiaotong Univ., Chengdu, China
Abstract :
Digital peak current (DPC) controlled switching dc-dc converters operating in discontinuous conduction mode (DCM) with four different digital pulse-width modulations are studied in this paper. The control laws by using four modulation methods are derived and compared with buck converter as an example. Their stabilities are also analyzed. Experiment studies are performed to compare the transient performance among four modulation methods. Experimental results show that DPC with trailing-triangle modulation has the fastest transient response to load variation.
Keywords :
DC-DC power convertors; PWM power convertors; digital control; electric current control; switching convertors; transient response; buck converter; digital peak current controlled converter; digital pulse-width modulation; discontinuous conduction mode; switching DC-DC converter; trailing-triangle modulation; transient response; Buck converters; DC-DC power converters; Digital control; Digital modulation; Load management; Pulse modulation; Pulse width modulation converters; Stability analysis; Switching converters; Transient response;
Conference_Titel :
Power Electronics and Motion Control Conference, 2009. IPEMC '09. IEEE 6th International
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-3556-2
Electronic_ISBN :
978-1-4244-3557-9
DOI :
10.1109/IPEMC.2009.5157405