Abstract :
This paper mentions the integrated design strategy and process control system, describing the problems in each stage associated with this design strategy, when applied to a spray drying tower for natural dyes. Initially, part of a phenomenological based semiphysical model of concentrated parameters, which describes the main dynamic process and has been validated in another work. Then, the control pairing is established to proceed with controllability analysis using Lie Algebra´s. Once, the regions of controllability of the process are established, a PID controller is tuned. Finally the model is simulated in an open loop and a closed loop to show the advantages of simultaneous design approach.
Keywords :
closed loop systems; control system synthesis; controllability; design engineering; drying; open loop systems; process control; three-term control; PID controller; closed loop control; controllability analysis; design strategy; lie algebra; natural dye; open loop control; phenomenological based semiphysical model; process control system; spray drying tower; Decision support systems; Control Tuning; controllability; integrated design; spray dryer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Robotics Symposium, 2011 IEEE IX Latin American and IEEE Colombian Conference on Automatic Control and Industry Applications (LARC)
Conference_Location :
Bogota
Print_ISBN :
978-1-4577-1689-8
Type :
conf
DOI :
10.1109/LARC.2011.6086859
Filename :
6086859
Link To Document :
بازگشت