Abstract
The authors develop an epoxy-based no-flow underfill material for lead-free bumped flip-chip applications. Many epoxy resin/HMPA/metal acetylacetonate material systems have been screened in terms of their curing kinetics. Some potential base formulations whose curing peak temperatures are higher than 200°C are selected for further development towards fluxing no-flow underfill materials for lead-free solders. The proper fluxing agents are then developed for these potential base formulations. The effects of fluxing agents studied on the curing kinetics and cured material properties of the potential base formulations are studied in detail. Fluxing capability of the developed no-flow formulations is evaluated using the wetting test of lead-free solder ball on copper board. The instrumentation involved includes differential scanning calorimetry (DSC), thermo-mechanical analyzer (TMA), dynamic-mechanical analyzer (DMA), thermo-gravimetric analyzer (TGA), and a rheometer. DSC is used to study the curing kinetics of the prepared formulations and glass transition temperature (DSC Tg) of the cured formulations. TMA is used to investigate the heat distortion temperature (TMA Tg) and coefficient of thermal expansion (CTE). DMA is used to measure the storage modulus (E\´) and loss modulus (E") within the temperature range from 25°C to 250°C. TGA is used to investigate the outgassing during curing and thermal stability of the cured material systems. The rheometer is used to investigate the viscosity change versus temperature for the interested formulations
Keywords
differential scanning calorimetry; elastic moduli; environmental factors; flip-chip devices; glass transition; integrated circuit packaging; plastic packaging; printed circuit testing; reaction kinetics; reflow soldering; thermal analysis; thermal expansion; thermal stability; viscosity; 25 to 250 C; DSC; TGA; TMA; base formulations; coefficient of thermal expansion; cured material properties; curing kinetics; curing peak temperatures; dynamic-mechanical analyzer; epoxy resin/HMPA/metal acetylacetonate material systems; epoxy-based no-flow underfill material; fluxing agents; fluxing capability; glass transition temperature; heat distortion temperature; lead-free bumped flip-chip applications; lead-free solder ball on copper board; loss modulus; outgassing; rheometer; storage modulus; thermal stability; thermo-gravimetric analyzer; thermo-mechanical analyzer; viscosity change; wetting test; Copper; Curing; Environmentally friendly manufacturing techniques; Epoxy resins; Inorganic materials; Kinetic theory; Lead; Material properties; Temperature; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Advanced Packaging Materials: Processes, Properties andInterfaces, 2000. Proceedings. International Symposium on
Conference_Location
Braselton, GA
Print_ISBN
0-930815-59-9
Type
conf
DOI
10.1109/ISAPM.2000.869285
Filename
869285
Link To Document