DocumentCode :
2424358
Title :
Location of partial discharges in transformers
Author :
Gopalakrishnan, M. ; Paneerselvarn, M.A. ; Shreeshankar, R.B. ; Jayalalitha, S. ; Jayashankar, V.
Author_Institution :
Sri Venkateshwara Coll. of Eng., Sriperambudur, India
fYear :
2003
fDate :
19-22 Oct. 2003
Firstpage :
620
Lastpage :
623
Abstract :
A matched filter approach is proposed for the location of a partial discharge within a winding. The approach is very general and does not need isolation of the capacitively transferred components. Simulations are performed on a lumped parameter model of a layer winding to prove the feasibility of the method. Experiments are also performed on a layer winding in order to validate the method. It is possible to extend the method to the determination of location of PD during impulse tests.
Keywords :
electric breakdown; matched filters; partial discharges; transformer windings; transient response; capacitively transferred components; layer winding; lumped parameter model; matched filter approach; partial discharges; transformers; Correlators; Current measurement; Educational institutions; Fault location; Filtering; Matched filters; Partial discharges; Pollution measurement; Resistors; Transformers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2003. Annual Report. Conference on
Print_ISBN :
0-7803-7910-1
Type :
conf
DOI :
10.1109/CEIDP.2003.1254931
Filename :
1254931
Link To Document :
بازگشت