• DocumentCode
    2424688
  • Title

    Results of measurements of the HERA proton beam position monitors

  • Author

    Schütte, W.

  • Author_Institution
    DESY, Hamburg, West Germany
  • fYear
    1989
  • fDate
    20-23 Mar 1989
  • Firstpage
    1471
  • Abstract
    A beam position monitoring system has been designed for the 820-GeV HERA (Hadron-Electron Ring Accelerator) proton storage ring accelerator. There will be 243 directional coupler pickups in the ring; the vacuum, mechanical, and electrical properties of each were measured. The measurements ensure good quality and form the basis for determining the beam orbit position relative to the corresponding quadrupole axis. The results of the measurements and the alignment procedure are described
  • Keywords
    beam handling equipment; beam handling techniques; particle accelerator accessories; proton accelerators; storage rings; HERA proton beam position monitors; alignment procedure; beam orbit position; directional coupler pickups; electrical properties; mechanical properties; proton storage ring accelerator; quadrupole axis; vacuum properties; Directional couplers; Electric variables measurement; Extraterrestrial measurements; Mechanical factors; Mechanical variables measurement; Monitoring; Particle beams; Position measurement; Proton accelerators; Storage rings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/PAC.1989.73483
  • Filename