• DocumentCode
    2428756
  • Title

    High voltage, chopper for electrical traction applications using series connection of large GTO thyristors

  • Author

    Saadate, S. ; Le Doeuff, R. ; Periot, R.

  • Author_Institution
    GREEN, ENSEM, Nancy, France
  • fYear
    1989
  • fDate
    6-10 Nov 1989
  • Firstpage
    177
  • Abstract
    The authors present considerations for the series connection of GTOs (gate turn-off thyristors). Criteria for the selection of GTOs, design of snubbers, and adoption of GTO control are given. The advantages and drawbacks of the strategies used are discussed. Detailed experimental results concerning the GTO commutations and the snubber circuit are presented. The influence of important parameters, such as the load current, on the transient and steady-state voltage distribution on the GTOs is discussed. As series connection of GTOs is liable to be used in the high-voltage static converters utilized in rail traction systems, two industrial realizations are considered
  • Keywords
    choppers (circuits); power convertors; railways; thyristor applications; traction; GTO commutations; GTO control; GTO thyristors; chopper; electrical traction; gate turn-off thyristors; high-voltage static converters; load current; rail traction systems; snubbers; steady-state voltage distribution; transient voltage distribution; Capacitors; Choppers; Circuits; Delay; Rails; Snubbers; Steady-state; Thyristors; Voltage control; Wiring;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics Society, 1989. IECON '89., 15th Annual Conference of IEEE
  • Conference_Location
    Philadelphia, PA
  • Type

    conf

  • DOI
    10.1109/IECON.1989.69631
  • Filename
    69631