DocumentCode
2429071
Title
Solving problem of gas turbine and HRSG trip from hydraulic damper closing in combined cycle power plant
Author
Laohasongkram, Phiphat ; Leeragreephol, Surachart
Author_Institution
King Mongkut´´s Inst. of Technol., Bangkok
fYear
2007
fDate
17-20 Oct. 2007
Firstpage
1301
Lastpage
1305
Abstract
This paper addresses a technique to solve the problem of accumulated heat transfer in solenoid coil of the solenoid valve controlling hydraulic damper by using the switching technique with low frequency. This new method can result in saving the energy loss in solenoid coil. In addition, this technique aims to solve the fundamental problem by reducing direct heat transfer in solenoid coil of the solenoid valve and protecting complete gas turbine trip from the hydraulic damper closing failure and heat recovery steam generator (HRSG) trips from burnt solenoid coil of hydraulic damper. For this experiment and research, the data was collected from South Bangkok Combined Cycle Power Plant Block II. After using low frequency switching circuit technique the gas turbine trip as well as the ITRSG trip did not happen.
Keywords
boilers; combined cycle power stations; gas turbine power stations; heat transfer; hydraulic turbines; shock absorbers; solenoids; valves; accumulated heat transfer; combined cycle power plant; direct heat transfer; gas turbine trip; heat recovery steam generator trips; hydraulic damper closing failure; solenoid coil; solenoid valve; switching technique; Cogeneration; Coils; Frequency; Heat recovery; Heat transfer; Hydraulic turbines; Power generation; Solenoids; Temperature control; Valves; Combined Cycle Power Plant; Gas Turbine; Heat Recovery Steam Generator (HRSG); Solenoid Valve;
fLanguage
English
Publisher
ieee
Conference_Titel
Control, Automation and Systems, 2007. ICCAS '07. International Conference on
Conference_Location
Seoul
Print_ISBN
978-89-950038-6-2
Electronic_ISBN
978-89-950038-6-2
Type
conf
DOI
10.1109/ICCAS.2007.4406538
Filename
4406538
Link To Document