Abstract
We used multi component GPR data to perform time lapse measurements in a controlled experiment simulating DNAPL release. The DNAPL is well detected with parallel broadside y- and x- directed antenna and a perpendicular antennas y-directed source and an x-directed receiver, whereas the component acquired with perpendicular antenna x-directed source and y-directed receiver orientation is less effective. After 174 hours of the contamination injection and water flow activation, data still show pull up of reflections in correspondence of DNAPL injection.
Keywords
geophysical techniques; ground penetrating radar; radar antennas; radar receivers; DNAPL; dense nonaqueous phase liquid; multicomponent GPR data; parallel broadside directed antenna; perpendicular antenna directed receiver; perpendicular antenna directed source; time lapse measurement; time-lapse monitoring method; water flow activation; Antenna accessories; Glass; Ground penetrating radar; Monitoring; Permittivity; Receiving antennas; Reflection; DNAPL; GPR multicomponent; chlorinated solvent; laboratory experiment; time-lapse;
fLanguage
English
Publisher
ieee
Conference_Titel
Advanced Ground Penetrating Radar (IWAGPR), 2011 6th International Workshop on
Conference_Location
Aachen
Print_ISBN
978-1-4577-0332-4
Electronic_ISBN
978-1-4577-0331-7
Type
conf
DOI
10.1109/IWAGPR.2011.5963877
Filename
5963877
Link To Document