DocumentCode
2433564
Title
Notch filter design using theα-scaled sampling kernel and its application to power line noise removal from ECG signals
Author
Kim, K.J. ; Ku, J.H. ; Kim, I.Y. ; Kim, S.I. ; Nam, S.W.
Author_Institution
Hanyang Univ., Seoul
fYear
2007
fDate
17-20 Oct. 2007
Firstpage
2415
Lastpage
2418
Abstract
A new design approach is proposed for sharp notch FIR filters, whereby a modified alpha- scaled sampling kernel is utilized. In particular, the proposed approach provides closed-form formulae for filter coefficients, leading to an effective design procedure for sharp notch filters with given specifications. Simulation results demonstrate that the proposed design method yields high performance in removing the power line interference from ECG signals.
Keywords
FIR filters; electrocardiography; interference suppression; notch filters; power cables; signal denoising; signal sampling; ECG signals; alpha-scaled sampling kernel; notch FIR filters; power line interference; power line noise removal; Biomedical engineering; Computational complexity; Digital filters; Electrocardiography; Finite impulse response filter; Frequency; Interference; Kernel; Sampling methods; Signal design; Notch FIR filter design; modified α - scaled sampling kernel; power line interference;
fLanguage
English
Publisher
ieee
Conference_Titel
Control, Automation and Systems, 2007. ICCAS '07. International Conference on
Conference_Location
Seoul
Print_ISBN
978-89-950038-6-2
Electronic_ISBN
978-89-950038-6-2
Type
conf
DOI
10.1109/ICCAS.2007.4406767
Filename
4406767
Link To Document