• DocumentCode
    2433564
  • Title

    Notch filter design using theα-scaled sampling kernel and its application to power line noise removal from ECG signals

  • Author

    Kim, K.J. ; Ku, J.H. ; Kim, I.Y. ; Kim, S.I. ; Nam, S.W.

  • Author_Institution
    Hanyang Univ., Seoul
  • fYear
    2007
  • fDate
    17-20 Oct. 2007
  • Firstpage
    2415
  • Lastpage
    2418
  • Abstract
    A new design approach is proposed for sharp notch FIR filters, whereby a modified alpha- scaled sampling kernel is utilized. In particular, the proposed approach provides closed-form formulae for filter coefficients, leading to an effective design procedure for sharp notch filters with given specifications. Simulation results demonstrate that the proposed design method yields high performance in removing the power line interference from ECG signals.
  • Keywords
    FIR filters; electrocardiography; interference suppression; notch filters; power cables; signal denoising; signal sampling; ECG signals; alpha-scaled sampling kernel; notch FIR filters; power line interference; power line noise removal; Biomedical engineering; Computational complexity; Digital filters; Electrocardiography; Finite impulse response filter; Frequency; Interference; Kernel; Sampling methods; Signal design; Notch FIR filter design; modified α - scaled sampling kernel; power line interference;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control, Automation and Systems, 2007. ICCAS '07. International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    978-89-950038-6-2
  • Electronic_ISBN
    978-89-950038-6-2
  • Type

    conf

  • DOI
    10.1109/ICCAS.2007.4406767
  • Filename
    4406767