Abstract :
The effect of the wind velocity on a corona-point electrode in a point-to-plane arrangement is presented in this paper. An important relationship between the wind velocity, the electric field and the magnitude of the corona current was observed. The experiment is performed in a shielded room at the atmospheric pressure and temperature of Bogotá, Colombia (2.600 m over sea level). The wind velocity was controlled.
Keywords :
corona; earth electrodes; electric fields; thunderstorms; wind; corona-point electrode; distance 2600 m; point-to-plane arrangement; positive corona current; single-needle-electrode; thunderstorm-like conditions; wind velocity; Corona; Current measurement; Electric fields; Electrodes; Equations; Mathematical model; Voltage measurement; Corona current; Electric field; corona onset; wind velocity;