• DocumentCode
    2440583
  • Title

    Study of leaching capacity of Ammonium Chloride solution to Calcium in EDTA titration

  • Author

    Zhang, Fuhai ; Yang, Liguo ; Zhang, Lei ; Li, Yulong

  • Author_Institution
    Geotechnical Res. Inst., HoHai Univ., Nanjing, China
  • fYear
    2011
  • fDate
    24-26 June 2011
  • Firstpage
    753
  • Lastpage
    756
  • Abstract
    In order to control and test the quality of cement stabilized soil, EDTA titration method is widely used to test the cement dosage in highway engineering. Owing to differences between the actual operation and specifications, the cement dosage of cement stabilized soil can´t be controlled effectively. The change of leaching capacity of Ammonium Chloride solution to Calcium in cement stabilized soil was studied, getting the influence law and practical solutions were proposed.
  • Keywords
    ammonium compounds; calcium; cements (building materials); civil engineering; leaching; quality control; road building; soil; EDTA titration method; ammonium chloride solution; calcium; cement dosage; cement stabilized soil; highway engineering; leaching capacity; quality control; quality testing; Accuracy; Calcium; Fitting; Leaching; Road transportation; Soil; Water conservation; EDTA titration; coment dose; leaching capacity; standard curve;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Remote Sensing, Environment and Transportation Engineering (RSETE), 2011 International Conference on
  • Conference_Location
    Nanjing
  • Print_ISBN
    978-1-4244-9172-8
  • Type

    conf

  • DOI
    10.1109/RSETE.2011.5964385
  • Filename
    5964385