DocumentCode
2442669
Title
Determination of PCBs in Sediments by ASE and GC/MS
Author
Li, Li ; Song, Xiao-mei ; Mao, Jian ; Liu, Ying ; Yin, Xuebin ; Liu, Houqi
Author_Institution
Anhui Univ. of Sci. & Technol., Huainan, China
fYear
2011
fDate
24-26 June 2011
Firstpage
1100
Lastpage
1103
Abstract
The method was established for determination of PCBs in sediments by accelerated solvent extraction, Florisil column purification and selected ion GC/MS. It was good linear relationship between PCBs concentrations and instrument responses, high sensitivity, and the recovery from 84. 3% to 103.4%, RSD from 9. 5% to 12. 2%. The test result of standard reference soil sample was correct.
Keywords
geochemistry; geophysical techniques; sediments; soil; Florisil column purification; PCBs concentrations; accelerated solvent extraction; gas chromatography; mass spectrometry; polychlorinated biphenyls; sediments; standard reference soil sample; ASK; GC/MS; PCBs; Sediment;
fLanguage
English
Publisher
ieee
Conference_Titel
Remote Sensing, Environment and Transportation Engineering (RSETE), 2011 International Conference on
Conference_Location
Nanjing
Print_ISBN
978-1-4244-9172-8
Type
conf
DOI
10.1109/RSETE.2011.5964472
Filename
5964472
Link To Document