• DocumentCode
    2444331
  • Title

    Implementation of the Personal Emergency Response System using a 3-axial Accelerometer

  • Author

    Jeon, A.Y. ; Kim, J.H. ; Kim, I.C. ; Jung, J.H. ; Ye, S.Y. ; Ro, J.H. ; Yoon, S.H. ; Son, J.M. ; Kim, B.C. ; Shin, B.J. ; Jeon, G.R.

  • Author_Institution
    Pusan Nat. Univ., Busan
  • fYear
    2007
  • fDate
    8-11 Nov. 2007
  • Firstpage
    223
  • Lastpage
    226
  • Abstract
    The aged are faced with increasing risk for falls. The aged have the easily fragile bones than others. When falls have occurred, it is important to detect this emergency state because such events often lead to more serious illness or even death. A implementation of PDA system, for detection of emergency situation, was developed using 3-axis accelerometer in this paper as follows. The signals were acquired from the 3-axis accelerometer, and then transmitted to the PDA through Bluetooth module. This system can classify the human activity, and also detect the emergency state like falls. When the fall occurs, the system generates the alarm on the PDA. If a subject does not respond to the alarm, the system determines whether the current situation is an emergency state or not, and then sends some information to the emergency center in the case of urgent situation. Three different studies were conducted on 12 experimental subjects, with results indicating a good accuracy. The first study was performed to detect the posture change of human daily activity. The second study was performed to detect the correct direction of fall. The third study was conducted to check the classification of the daily physical activity. Each test was lasted at least 1 min. in third study. The output of acceleration signal was compared and evaluated by changing a various posture after attaching a 3-axis accelerometer module on the chest. The newly developed system has some important features such as portability, convenience and low cost. One of the main advantages of this system is that it is available at home healthcare environment. Another important feature lies in low cost to manufacture device. The implemented system can detect the fall accurately, so will be widely used in emergency situation.his paper, the PDA system was developed using the 3-axis accelerometer. First, the signals were acquired from the 3-axis accelerometer, and then transmitted to the PDA through Bluetooth module, Acode-300- - (Chipsen, Co. Korea). This system can classify the human activity, and also detect the emergency state like falls. When the fall is detected, the system generates the alarm on the PDA. If a subject does not respond to the alarm, the system determines that the current situation is an emergency state, and then sends some information to the emergency center.
  • Keywords
    Bluetooth; emergency services; geriatrics; health care; medical computing; patient monitoring; telemedicine; 3-axial accelerometer; Bluetooth; PDA system; alarm system; geriatrics; home healthcare; personal emergency response system; Acceleration; Accelerometers; Aging; Bluetooth; Bones; Costs; Event detection; Face detection; Humans; Testing; Alarm System; Ambulatory monitoring; Classification of activity; Emergency detection; and 3-axis accelerometer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information Technology Applications in Biomedicine, 2007. ITAB 2007. 6th International Special Topic Conference on
  • Conference_Location
    Tokyo
  • Print_ISBN
    978-1-4244-1867-1
  • Electronic_ISBN
    978-1-4244-1868-8
  • Type

    conf

  • DOI
    10.1109/ITAB.2007.4407387
  • Filename
    4407387