DocumentCode :
2447086
Title :
Research on the Application of the Linear PID to the Thermal Medicine Filler
Author :
Zhao Jie ; Zheng Peng ; Fan Jianmin ; Xue Yuanqing
Author_Institution :
Sch. of Inf. Technol. & Eng., Tianjin Univ. of Technol. & Educ., Tianjin, China
fYear :
2012
fDate :
1-3 Nov. 2012
Firstpage :
202
Lastpage :
205
Abstract :
Temperature control system of the Thermal Medicine Filler is a large inertia, pure time-delay, and nonlinear system which is seriously influenced by surrounding factor. Traditional PID control algorithm couldn´t adjust PID parameters in real-time according to the need, so it is unsuitable for nonlinear system generally. Based on the temperature of return water in the thermal medicine filler, a new method is proposed. It can online adjust PID parameters automatically. It has greatly improved the effect of the temperature control.
Keywords :
biomedical equipment; delays; nonlinear systems; temperature control; three-term control; linear PID control algorithm; nonlinear system; pure time-delay; temperature control system; thermal medicine filler; Containers; Educational institutions; Heating; Humans; Liquids; Temperature measurement; linear PID; temperature control; thermal medicine filler;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Intelligent Networks and Intelligent Systems (ICINIS), 2012 Fifth International Conference on
Conference_Location :
Tianjin
Print_ISBN :
978-1-4673-3083-1
Type :
conf
DOI :
10.1109/ICINIS.2012.47
Filename :
6376521
Link To Document :