Abstract :
A duty ratio control scheme for inverter-fed induction machines using the direct torque control (DTC) method is presented. An improved steady state torque response was achieved using the duty ratio control and had shown less torque ripple compared to the conventional DTC. Fuzzy logic control has been used to implement the duty ratio during each switching cycle using the torque and flux errors as inputs. Simulation results using SIMULINK gave results that justify the claims.
Keywords :
fuzzy control; induction motor drives; invertors; machine control; torque control; 3 hp; SIMULINK; direct torque control; duty ratio control scheme; flux errors; fuzzy logic control; induction machines; induction motor drive; inverter-fed induction machines; spatial flux vector control; steady state torque response; switching cycle; torque ripple minimization; Equations; Fuzzy logic; Induction machines; Induction motors; Pulse width modulation; Pulse width modulation inverters; Stators; Steady-state; Torque control; Voltage;